SATO CL4NX Programming Reference Manual page 484

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

Block
0
Data
[Coding sample8] (data format set to ASCII)
When writing 13-byte characters "4912345678904" to NTAG213 RFID tag, locking 4 continuous
blocks simultaneously with "Ignore RFID tag error" omitted
<A>
<V>50<H>50<BD>3020654912345678904
<RK>1,D13,4912345678904,lck:F000
<Q>2
<Z>
Memory data after execution
Block
0
1
Data
[Coding sample9] (data format set to ASCII)
In case where 13 bytes characters of [4912345678904] is recorded to RFID tag of NTAG215 from a
block of user memory 12 and target block is locked simultaneously (lock L and BL at the same time),
with "Ignore RFID tag error" omitted
<A>
<V>50<H>50<BD>3020654912345678904
<RK>1,D13,4912345678904,ict:04,wsb:12,dlk:010001
<Q>2
<Z>
Memory data after execution
0
1
Block
Data
[Supplemental explanation]
This command allows to print for continuous printing, cutter printing, dispenser printing and tear-
off.
1
2
3
4.....8
4912
specify the block to start writing with wsb:
Refer to "ISO/IEC14443 Type A memory structure"
2
3
4
5
4912
3456
Specify lock block with lck:
Locked block
specify the block to start writing with wsb:
Refer to "ISO/IEC14443 Type A memory structure"
2
3
4...15
16
17
4912
3456
Becomes Read only with dlk:
9
10
11
3456
7890
6
7
Any data outside of the range written
7890
4XXX
to is not affected.
* XXX is data present before this
command was set.
18
19
20...31
7890
4XXX
482
12
13.....15
Any data outside of the range written
4XXX
to is not affected.
* XXX is data present before this
command was set.
8.....38
39
32...47
48.....129
Data in the byte
position outside for
writing
is
maintained.
*XXX is the data existed before the write.
dlk: disables Read only
40
130 131 132 133 134