[ESC+GC] BMP File Call
Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
Invoking and printing out the data registered with Registration of BMP File <GT>.
[Format]
<GC>aaa
•
Parameter
a [Registration number]
Valid Range : 1 to 999
[Coding Example]
<A>
<V>100<H>100
<CC>1
<GC>1
<Q>2
<Z>
[Supplementary Explanation]
•
Specify the card slot number used for Card Slot <CC> prior to this command <GC> by all
means.
•
Rotation <%> and Enlargement <L> are available for the invoked data.
•
The error occurs when unused or the slot which this product is allocated is specified.
[Note]
•
Do not turn the printer's power off when accessing to the memory. When the printer power is off
while memory accessing, the data in the accessed media may be corrupted.
Parent topic
Memory Card Command
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
391
GC
<47>
<43>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
aaa