[ESC+2D12] Micro PDF417
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying Micro PDF417.
[Format](Setting part)
<2D12>,aa,bb,c,dd(,e)
•
Parameter
a [Minimum module width] = Valid Range : 01 to 27 dots
b [Minimum module height] = Valid Range : 01 to 72 dots
c [Number of data code words per row] (Cols) = Valid Range : 1 to 4
d [Number of rows per symbol] (Rows) = Valid Range : 2 rows
e [Binary mode]
0 : Normal, When omitted 0 (Can be omitted)
1 : Binary mode
[Format](Data part)
<DN>mmmm,n...n : Binary mode is Binary mode
<DS>n...n : Binary mode is Normal
•
Parameter
m [Number of data] = Valid Range : 0001 to 0366 bytes
n [Print data] = Data
[Coding Example]
Module width: 02 dots, Minimum module height: 04 dots, Data code word per row: 1, Rows per
symbol: 14
<A>
<V>100<H>200<2D12>,02,04,1,14
<DN>0010,0123456789
<Q>2
<Z>
ESC
2D12
<1B>
<32>
<44>
16
16
Nil
When the power is OFF
Valid range within items
Valid range between items
228
<31>
<32>
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
,aa,bb,c,dd(,e)