Disconnection timeout period (SPP layer)
0 second (Initial value)
Disconnection timeout period (LMP layer)
60 seconds (Initial value)
Parameter
Protocol
Receive buffer size
2.95 MB
0 MB
Near Full
Release Near
Full
Pairing
Keep link keys for 10 devices
CoD (Class of Device)
Major service class: Unspecified
Major device class: Imaging major class
Minor device class: Printer
supervision timeout
Initial value=20 seconds (Changeable from host)
[Supplementary Explanation]
Printer operates in slave mode. Before establishing connection, specify Bluetooth Device
address (BD address) from the master.
Connection may not be established when master's authentication mode, packet type, and PIN
code are different from above setting. In that case, confirm authentication level and PIN code by
[Settings] menu > [Tools] menu > [Test Print] > [Configure List], match with master setting and
try reconnection.
Bluetooth interface and printer is connected by internal serial interface , and transfer speed is
115200bps.
When Bluetooth LINK is lost (e.g. out of service area), disconnects from the printer after
supervision timeout period has passed.
When Bluetooth communication is disconnected while sending print data (STX<A> to <Z>ETX),
the received data is discarded after disconnection time-out period has passed. It is required
to resend print data (STX<A> to <Z>ETX) when time out occurs. Time out is not monitored if
disconnection time out period is set to 0.
Setting item
Status 3
Status 4 (Initial value)
None
2.95 MB
Remaining 0.95 MB
Remaining 1.95 MB