SATO CL4NX Programming Reference Manual page 573

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

Symbol
d
Bytes of data
e
Data
When the command is issued specifying "H2" (UID data) for the identifier
cc:e...e
Symbol
c
Identifier
e
Data
When the command is issued specifying "H3" (option flag data) for the identifier
cc:e...e,ff:h...h,ii:k...k
Symbol
c / f / i
Specify memory
e / h / k
Data
[Maximum return data]
Command identifier
H1:USER data
H2:UID data
H3:Option flag data
(DSFID data + AFI data + EAS bit)
Parameter name
Data input and output form is which case of ASCII or HEX, but, as for
the unit, the value becomes same for a byte.
Refer to [Maximum return data] below.
Parameter name
UI: UID data
Refer to [Maximum return data] below.
Parameter name
DS: DSFID data
AF: AFI data
EA: EAS bit
Refer to [Maximum return data] below.
Description
Description
Description
Current inlet type
02:ICODE
160(ASCII)
320(HEX)
03:Tag-it
256(ASCII)
512(HEX)
05:my-d
(Custom)
1000(ASCII)
2000(HEX)
(ISO)
992(ASCII)
1984(HEX)
02:ICODE
16(HEX)
03:Tag-it
05:my-d
02:ICODE
Both of DSFID data,AFI data,EAS bit
03:Tag-it
2(HEX)
05:my-d
571
Return number of bytes