[Supplementary Explanation]
Specification of [B] has shorter program description than that of specification [H]; and, transfer
data length is 50 percent shorter. This could be advantage in data capacity.
Specification of Rotation <%> and Enlargement <L> are available.
<L> command should be placed just before <G> command.
When using rotation <%> and enlargement <L> commands at the same time, specify <%>
command before <L>.
The crosswise maximum byte and lengthwise maximum byte are specified in the table below,
however, it is possible to specify up to 999 bytes to have compatibility with the old model.
The graphic data less than 2,937,600 bytes can be printed.
The calculation of graphic data size is [crosswise maximum byte x lengthwise maximum byte x
8].
[Initial value of parameter and Valid Range]
Model
CL4NX
CL6NX
*1 Valid range when "Head Base Position" is set to "Standard".
*2 Valid range when "Head Base Position" is set to "Left-justify".
Parent topic
Graphic Command
Head density
203 dpi
305 dpi
609 dpi
203 dpi
305 dpi
322
Crosswise max. bytes
104
156
312
*1
152
*2
167
*1
248
*2
251
Lengthwise max. bytes
400
600
999
400
600