<DN>0010,0123456789
<DS>1,123
<Q>1
<Z>
[Supplementary Explanation3]
Parameter part to be followed by Data part. Data part and data part should be specified in a row.
When don't specify in a row, print result may not be secured.
Total number of data (n) need to be less than 7000 bytes. Maximum number of blocks in data
part specified in a row is 200.
[Coding Example 3]
Error correction level: 7%, Size of one side of cell: 05, Data setup mode: Manual setup,
Concatenation mode: Normal, Version 5
<A>
<V>100<H>200<2D30>,L,05,0,0
<QV>5
<DS>1,012345
<DN>0004,6789
<Q>1
<Z>
[Supplementary Explanation4]
Specify <QV> command between <2Dxx> and <DN>/<DS>.
When resulted in a parameter error, it will be handled in the same manner of no specification.
It does not become a parameter error from 00 to 40 (Set the value within the range
corresponding to each model).
For MODEL2, the setting range is from 00 to 40.
Sending the data exceeding the data size of specified version will result in error and QR code is
not printed.