[Coding Example]
Symbol Type: Compact, ECC Percentage: Default, Symbol Size: 2 layer, Structured Append:
Without append, Message ID: No, Message ID for structured bound symbol: None, Barcode Data:
THIS IS TEST.
<A>
<V>0100<H>0100<L>0404
<2D70>,1,0,2,0,N,<DS>THIS IS TEST
<Q>1
<Z>
Generated Label
[Notes]
When parameters other than the description are specified, symbol may not print.
When the size of the Aztec code is small, the symbol might not be able to read according to
the performance of the scanner. In that case, please magnify the size of the symbol to make it
large enough by using <ESC>+L command maintaining the same ratio of magnification for both
length and width.
The smallest symbol size is 15x15 modules and largest is 151x151 modules. Available Aztec
code formats and its maximum capacity are as follows:
Symbol size table
Parameter c
1
2
3
4
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Format
15x15 Compact
13
19x19 Compact
40
23X23 Compact
70
27X27 Compact
110
31X31
128
37X37
178
41X41
232
45X45
294
49X49
362
53X53
433
57X57
516
61X61
601
67X67
691
71X71
793
75X75
896
79X79
1008
83X83
1123
87X87
1246
280
Digit
Text
12
33
57
89
104
144
187
236
291
348
414
482
554
636
718
808
900
998
Binary data
6
19
33
53
62
87
114
145
179
214
256
298
343
394
446
502
559
621

Hide quick links: