[ESC+0] Partial Edit

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Editing the portion in the previous print data.
[Format]
<0>
[Coding Example]
[DEF], a part of print data, is changed to [123].
First label
<A>
<V>100<H>200<P>2<L>0202<XM>ABC
<V>100<H>200<P>2<L>0202<XM>DEF
<Q>1
<Z>
Second label
<A>
<0>
<V>100<H>200<P>2<L>0202<XM>123
<Q>1
<Z>
1st label
ABC
DEF
[Supplementary Explanation]
Use this command to edit only one part of previous print data.
Invoke the previous print data with this command to edit and print out. In this case, specify the
part of previous data to edit, and send change data to it.
Specified portion in the previous data will be cleared.
If Rotation <%> is included in the specified editing portion, keep it for partial editing.
Use this command with fixed pitch, same font or same digit number.
Parent topic
Modification Command
ESC
<1B>
16
Nil
When the power is OFF
Valid range within items
Valid range between items
2nd label
ABC
1 2 3
57
0
<30>
16
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.
Partial
edit
Parameter
Nil