[Esc+Ru] Uid Return (Iso/Iec15693) (Cl4Nx Only) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

[ESC+RU] UID return (ISO/IEC15693) (CL4NX Only)

Command
Hexadecimal code
Initial Value
Valid range and term of
command
[Function]
This command is used to return UID together with the result when data is written to the RFID tag by
the <RK> command.
[Format]
Return specification: <RU>,aa
Request to return: [DC2]PK
Parameters
Symbol
aa
Identifier
[[DC2]PK return data format (normal)]
[STX]a...a,b,c,d...d [CR][LF] [ETX]
[Return data]
Symbol
a
b
c
d
ESC
<1B>
16
aa=00
When turning off the power
Valid range within item
Valid range between items
Parameter name
Parameter name
Total number of data byte
* This is the total number of bytes after parameter b. The
delimiting comma between parameters a and b, and the
ETX are not included.
Write result status
* Text format
Error symbol
UID return data
RU
<52>
<55>
16
16
The set command is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter is in effect until a new specification is
made.
00: Not returned (default
setting)
01: Validate return.
Obtain return data by
sending [DC2]PK.
449
Parameter
,aa
Valid range
Two character fixation
Valid range
Data size from the first write result
status until before [ETX]
Maximum 5 digits
0: Write failure
1: Write success
* Note: Specified in text format.
N: No error
U: UID read error
A: All errors
* Note: Specified in text format
Refer to "UID return data " as
below

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents