[ESC+TW] Option Waiting Time

Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifies waiting time for optional device.
[Format]
<TW>aaa
Parameter
aaa
[Waiting time] = Valid range   :   000, 005 to 200 (unit: 100ms)
[Coding Example] (waiting time = 1.5 seconds)
<A>
<TW>015
<Z>
[Supplementary Explanation]
This command specifies, in Tear-off mode, the waiting time between print completion and Tear-
off motion.
The set parameter becomes valid soon after receiving the command and will be retained after
power off.
Parent topic
System Command
ESC
<1B>
16
aaa = 000
When the power is OFF
Valid range within items
Valid range between items
362
TW
<54>
<57>
16
16
The set parameter is maintained.