[ESC+2D70] Aztec Code
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifies Aztec Code.
[Format] (Setup part)
<2D70>,a,bb,cc,dd,e,f...f
•
Parameter
a [Symbol Type]
0 : Full Range Symbol
1 : Compact Symbol
b [ECC Percentage]
0 : Default error correction level
01 to 99 : Error correction percentage
c [Symbol Size]
0 : Automatic minimization
1 to 4 : 1 to 4 – layer (Compact Symbol) * Following symbol size table reference.
4 to 32 : 4 to 32 – layer (Full Range Symbol) * Following symbol size table reference.
d [Number of symbols for structured append]
0 : Encodes without append
1 : Automatic Setting
2 to 26 : Append structured blocks
e [Message ID]
Y : Specify Message ID for structured bound symbol
N : No Message ID
f [Message ID for structured bound symbol]
Printable ASCII string (0x21 to 0x7E) with maximum 24 bytes.
[Format] (Data part)
<DS>n..n // for ASCII data
<DN>mmmm,n..n // for Binary data
•
Parameter
m [Number of Data] = 0001 to 1914
- Set this parameter when Print data are in Binary.
n [Print data] = Data
- When selecting [1BH], make sure to specify [1BH,1BH].
- When selecting [FNC1], make sure to specify [1BH,30H]
- When selecting [ECI], make sure to specify [1BH,*]. ('*' refers from 31H to 36H. )
ESC
2D70
<1B>
<32>
<44>
16
16
Nil
When the power is OFF
Valid range within items
Valid range between items
279
<37>
<30>
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Parameter
,a,bb,cc,dd,e,f...f