Esc+Rk Rfid Write(Iso/Iec14443 Typea) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

16.10 RFID
16.10
ESC+RK
RFID Write
TypeA)
(ISO/IEC14443 TypeA)
Command
ESC
HEX code
<1B>
16
Initial value
Nil
When power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifies the data to write on RFID tag that supports ISO/IEC14443 Type A.
[Format]
[When setting NFC(NDEF) format user data]
<RK>a(,b),NFC:x(,ict:xx)(,lck:xxxx)(,dlk:yyyyyy)(,spl:x)(,ptl:xx)(,ecd:x)(,lgc:aaaaa...aaaa)(,idt:xxx...xxx)
(,ndd:mmmm,nnnnn...nnnn)(,hma:xxxxxxxxxxxx)(,dnm:aaaaa...aaaa)(,dcl:xxxxxx)(,scl:xxxx)(,ver:x,x) (,rfb:x)
(,ssi:xxx,aaa...aaa)(,nky:xxx,aaa...aaa)(,atp:xxxx)(,etp:xxxx)(,amc:e)(,ams:hhh)(,amb:f)(,ame:g)(,nce:l)(,cfl:o)
(,lma:ii)(,prt:j)(,acl:k)(,lim:p)(,apw:ssssssss)(pck:tttt)(,psw:ssssssss)(,sa0:uu)(,sa1:vv)(,sak:wwwww...wwww)
(,aky:wwwww...wwww)(,fsw:r)
[When setting free format user data / when there is no user data]
<RK>a(,b),Dmmmm,n~n(,NFC:f) (,ict:xx)(,wsb:sss)(,lck:xxxx)(,dlk:yyyyyy)(,amc:e)(,ams:hhh)(,amb:f)(,ame:g)
(,cfl:o)(,lma:iii)(,prt:j)(,acl:k)(,lim:p)(,apw:ssssssss)(pck:tttt)(,psw:ssssssss)(,sa0:uu)(,sa1:vv)(,sak:wwwww...wwww)
(,aky:wwwww...wwww)(,fsw:r)
●Parameter
Specification of inlet type
Valid range for models with module supporting ISO/IEC14443 TypeA:1
a
1:NTAG、MIFARE、my-d(supports NFC)
Ignore RFID tag error (omissible)
Valid range:0 to 9
0: Unspecified
This mode stops every time a tag error occurs.
1 to 9: Specify how many labels to ignore for RFID tag error
b
When tag error occurs, retries with next label up to the maximum number of labels to ignore. This mode will
stop the printer when the series of tag errors exceeds the specified number.
Note: If this parameter is omitted, the number of retries set under the menu Interfaces-> RFID->Retries
([DC2]PA's identifier IF, MAX_RETRY_LABEL) is applied instead
RFID
Write(ISO/IEC14443
RK
Parameter
<52>
<4B>
Refer to Parameters page
16
16
The set command will not be maintained.
The set parameter becomes invalid.
The set parameter becomes invalid
349
ESC+RK