Installing or replacing batteries
Approximately one month prior to the end of the battery life, a Low Battery Trouble signal is
indicated at the PIM400 and a Trouble signal will be sent to the access control panel.
1. Remove the battery cover.
2. Remove the battery bracket. Do not allow the battery pack to hang from the wires.
3. Install the new batteries (install only new AA Alkaline batteries). Make sure the batteries
are installed in the correct orientation.
4. Reinstall the battery pack and battery bracket.
5. Reinstall the battery cover, making sure the connector is above the battery pack.
CAUTION! Danger of explosion if battery is incorrectly replaced! Replace only
with the same or equivalent type. Dispose of used batteries according to the
manufacturer's instructions.
This product has been evaluated for ULC-S319 compliance with AA and coin cell batteries
listed below. For installations requiring ULC-S319, these battery models should be used.
AA batteries: Duracell PC1500, MN1500; Energizer E91, EN91, AX91, XR91;
RayoVac 815, 815-HE
Coin cell batteries: Energizer CR2025, CR2032; Maxell CR2025, CR2032,
Panasonic CR2025, CR2032; RayoVac KECR2025, KECR2032
Four Battery Configuration
Low battery indications
Replacement of batteries does not affect any programmed data. Battery voltage
L
can be checked with the SUS.
When in a low battery condition the lock may operate but not have sufficient
L
power to communicate with the SUS. When intitiating SUS communication,
the Schlage button will light solid red for one second to indicate power is not
sufficient. If this should occur, change the batteries immediately.
Condition
Low battery
No beeps
Low battery condition is reported
to the Access Control Panel.
Battery failure
No LED or beeps
(configured
Valid credentials do not grant
by SUS)
access
12 • Schlage • AD-400 user guide
Batteries
Indicator
Eight-Battery Configuration
Replace batteries immediately to avoid
failure.
Replace batteries immediately.
Mechanical override key must be used
to unlock the lock.