Schlage PIB300 User Manual page 1297

Hide thumbs Also See for PIB300:
Table of Contents

Advertisement

Battery failure modes
The battery failure mode is set using the SUS. See the SUS user guide for more
L
information.
Mode
Fail As-Is (default)
Fail Unlocked
1
Fail Locked
1
1 Fail Unlocked and Fail Locked modes are not available if lock is externally powered.
The AD-400/AD-401 may be connected to external power using a UL294 listed power supply
for UL installations, and a power supply that complies with CAN/UL-S318 or CAN/ULC-S319
for cUL installations. The power supply must be capable of sourcing at least 250 mA @ 12 or
24 VDC (Schlage PS902, PS904, PS906).
DO NOT connect both external power and AA batteries at the same time.
When externally powered, the lock will always fail as-is if power is lost.
The beep indicator may be enabled or disabled using the SUS. See the SUS User Guide for
more information.
Extended (Toggle) unlock
Card presented and not read
Card presented and read
No communication with PIM400 or the ACP when
card presented
Access denied
Access granted, momentary unlock (motor runs) 1 green
Relock (motor runs)
Lock remains in current state until batteries are replaced.
Lock unlocks and remains unlocked until batteries are replaced.
Lock locks and remains locked until batteries are replaced.
External power supply
LED and beep reference
Action
Description
+
Polarity Required
!
Schlage button LEDs
2 green
None
None
1 red
Controlled by ACP via PIM400
1 red
13 • Schlage • AD-400 user guide