Panasonic FP-E Programming Manual page 242

Fp series
Table of Contents

Advertisement

Basic Instructions
Keyword setting
SYS1, M
Port used
TOOL: Tool port
COM1: COM. 1 port
COM2: COM. 2 port
Response time
WAIT0 to WAIT999 (n: 0 to 999)
If the communication mode or the MOD BUS RTV mode has been set to the computer link mode, the set time
is the scan time x n (n: 0 to 999).
If the communication mode has been set to the PLC link mode, the set time is n µs (n: 0 to 999).
If n = 0, the delay time set by this instruction will be set to "None".
Precautions during programming
The settings should not be changed as long as there is no trouble, to
prevent the PLC link from getting unstable.
This instruction is valid only if the setting on the controller side has been
set to the computer link mode or the PLC link mode.
The instruction should be executed at the beginning of the program, at
the rise of R9014. The same value should be set for all linked PLCs.
Executing this instruction does not change the settings in the system
registers.
If changing the settings, a value of at least twice should be set.
We recommend using differential execution with this instruction.
When the power supply to the PLC is off, the settings set by this
instruction are cleared. (The set value will become 0.) If the mode is
switched to the PROG. mode after the instruction has been executed,
however, the settings will be retained.
If a commercial RS232C/RS485 converter is being used in the PLC link
mode, this instruction should be programmed in all of the stations (PLCs)
connected to the link.
For No. 1 and No. 2 keywords, input 12 letters after "M" aligning to the
right. Separate No.1 and No.2 keywords with a comma "," and do not
use spaces. An operation error will occur.
[Example] If inputting (SYS1, M
Flag conditions
・Error flag (R9007):
・Error flag (R9008):
2 − 132
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
TOOL,WAITn
Input => M
C O M 1 , W A I T 2
Input a space after "M" to be 12 letter aligning to the right.
Turns on and stays on when:
Turns on for an instant when:
− Any character other than a keyword is specified
− There is no comma between No. 1 and No. 2 keywords
− The small letter of the alphabet is used to specify the keyword
− No communication cassette has been installed when COM1 or COM2 has
been set
COM1, WAIT2)
FPΣ/FP−X/FP0R