FP0/FP0R/FP−e/FPΣ/FP−X
Main program
INT0 program
INT5 program
INT0 input
INT5 input
Condition
How to start the interrupt program when executing the high−speed counter match
ON/match OFF instruction.
Set the counter by the system register. (It is not necessary to set the external interrupt.)
1
Describe the interrupt program on the program. The high−speed counter corresponds to the interrupt
2
program as below.
Interrupt
p
Program No.
P
N
INT0
INT1
INT2
INT3
INT4
INT5
INT6
INT7
INT8
INT9
INT10
INT11
INT12
INT13
Enable the setting by the ICTLinstruction.
3
Enable ICTL, H0, H9 −INT0 and INT7.
Start the match ON/match OFF instruction.
4
The program is executed when the conditions for the match ON/match OFF instruciton are met.
5
Example for clearing interrupt programs
Example:
S1: H100
Clears interrupts from specified input contact or target value
match interrupts.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Execution
Execution
on
off
on
off
Disabled
High−speed counter−initiated interrupt
FP0/FP−e
FPΣ/FP0R
ch0
ch1
ch2
ch3
DF
ICTL, H100, HFE
S1
S2
ICTL instruction
Execution
Execution
Enabled
FP−X Ry
ch0
ch0
ch1
ch1
ch2
ch2
ch3
ch3
ch4
ch5
ch6
ch7
ch8
ch9
chA
chB
Basic Instructions
FP−X Tr
ch0
ch1
ch2
ch3
ch4
ch5
ch6
ch7
2 − 107