6.8 CFM Linktrace Screen

Click Diagnostic > CFM Linktrace in the navigation panel to display this screen. Use this screen
to perform a link trace connectivity test on a link.
Figure 96 Diagnostic > CFM Linktrace
The following table describes the labels in this screen.
Table 70 Diagnostic > CFM Linktrace
LABEL
MD
MA
MEPID
Target
TTL
Test
Management Switch Card User's Guide
DESCRIPTION
Select an MD name.
If the drop-down list is empty, create an MD in the Switch > CFM screen.
Select an MA name under the selected MD.
If the drop-down list is empty, create an MA in the Switch > CFM > CFM maintenance
association screen.
Select an MEP ID to specify which MEP port on the device initiates the test.
If the drop-down list is empty, create an MA in the Switch > CFM > CFM maintenance
association > CFM endpoint screen.
Specify the destination of the link you are checking. You can select MEPID and enter a remote
MEP's ID or select MAC and enter a remote MEP's MAC address.
Set the maximum time period (1~63 seconds) the link trace test can continue for without a
response.
Click this to start the link trace connectivity test.
Chapter 6 Diagnostic Screens