Chapter 30 profile Commands
Table 366 profile Commands (continued)
COMMAND
846
usage: set <profile>
[xtucfecs <xtucfecs>]
[xtuces <xtuces>]
[xtucses
<xtucses>][xtucloss
<xtucloss>] [xtuclofs
<xtuclofs>]
[xtucuas <xtucuas>]
[xturfecs <xturfecs>]
[xtures <xtures>]
[xturses <xturses>]
[xturloss <xturloss>]
[xturlofs <xturlofs>]
[xturlprs <xturlprs>]
[xturuas <xturuas>]
[fullinit <fullinit>]
[xtuclols <xtuclols>]
DESCRIPTION
Creates an alarm VDSL2 line profile of 15
minute period alarm thresholds. A 0 has the
system ignore that threshold.
: profile name, up to 31 characters
profile
: the number of Forward Error
xtucfecs
Correction Seconds (FECS) allowed on the
system. 0~900 in seconds, 0 means disable.
: the number of Errored Seconds
xtuces
(ES) allowed on the system. 0~900 in
seconds, 0 means disable.
: the number of Severely Errored
xtucses
Seconds (SES) errors allowed on the
system. 0~900 in seconds, 0 means disable.
: The number of Loss of Signal
xtucloss
Seconds(LoSS) allowed on the system.
0~900 in seconds, 0 means disable.
: The number of Loss of Framing
xtuclofs
Seconds (LoFS) allowed on the system. 0~900 in
seconds, 0 means disable.
: The number of UnAvailable
xtucuas
Seconds (UAS) errors allowed on the
system. 0~900 in seconds, 0 means disable.
: The number of Forward Error
xturfecs
Correction Seconds (FECS) allowed on CPE
devices. 0~900 in seconds, 0 means disable.
: The number of Errored Seconds (ES)
xtures
allowed on CPE devices. 0~900 in seconds, 0
means disable.
: The number of Severely Errored
xturses
Seconds (SES) errors allowed on CPE devices.
0~900 in seconds, 0 means disable.
: The number of Loss of Signal (Los)
xturloss
errors allowed on CPE devices. 0~900 in
seconds, 0 means disable.
: The number of Loss of Framing
xturlofs
(LoF) errors allowed on CPE devices. 0~900 in
seconds, 0 means disable.
: The number of Loss of PoweR (LPR)
xturlprs
errors allowed on CPE devices. 0~900 in
seconds, 0 means disable.
: The number of UnAvailable Seconds
xturuas
(UAS) errors allowed on CPE devices. 0~900 in
seconds, 0 means disable.
: The number of times a full
fullinit
initialization is allowed to fail.
0~4294967295 in times, 0 means disable.
: The number Loss of Link
xtuclols
Seconds (LOLS) allowed. 0~900 in seconds,
0 means disable.
Management Switch Card User's Guide
P
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc1024gMsc1224gMsc1024gbMsc1024gcMsc1224gb

Table of Contents