Chapter 9 Subscriber Port Setup Screens
Table 111 SHDSL Port Setup (continued)
LABEL
SHDSL Profile
Span Alarm
Profile
Stuc Alarm Profile
Stur Alarm Profile
Mode
Customer
Information
TEL
Advanced
Features
Apply
Cancel
250
DESCRIPTION
Select a profile of SHDSL settings (such as the transfer rate, wire pair and signal to noise
ratio settings) to assign to this port. Use the SHDSL Profile screen to configure SHDSL
port profiles.
Note: All the SHDSL ports in an n-wire group must use the same profile.
Select an alarm profile to define the thresholds that trigger an alarm on the port when
exceeded. This alarm profile is for the whole span. This is the entire connection including
any SHDSL regenerators that might be located between the STU-C (SHDSL Termination
Unit - Central) and STU-R (SHDSL Termination Unit - Remote) end points. An SHDSL
regenerator amplifies the SHDSL signal in order to increase the connection distance.
Select an alarm profile to define the thresholds that trigger an alarm on the port when
exceeded. This alarm profile is for the STU-C (SHDSL Termination Unit - Central) end
point.
Select an alarm profile to define the thresholds that trigger an alarm on the port when
exceeded. This alarm profile is for the STU-R (SHDSL Termination Unit - Remote) end
point.
Select the type of line coding to use for this port. The STU-R must also support the same
type. Select auto to have the system automatically select the proper line coding type for
the highest possible data rate. PAM 32 is more efficient than PAM 16 and can deliver
higher data rates over short distances.
Enter information to identify the subscriber connected to this DSL port. You can use up to
31 printable English keyboard characters (including spaces and hyphens).
Enter information to identify the telephone number of the subscriber connected to this
DSL port. You can use up to 15 English keyboard characters (including spaces and
hyphens).
Click the Setup button to open a screen where you can configure the SHDSL port's
detailed settings. See
Section 9.10.2 on page 253
Click Apply to have the specified DSL port use the selected IGMP filter profile.
Click Cancel to set the fields back to the settings that you last retrieved.
for more information.
Management Switch Card User's Guide