ZyXEL Communications MSC1000G User Manual page 155

Management switch card
Hide thumbs Also See for MSC1000G:
Table of Contents

Advertisement

Table 60 Alarm Descriptions (continued)
ALARM
ADSL_TCA_SES
ADSL_TCA_UAS
SHDSL_TCA_ATTEN
SHDSL_TCA_SNRM
SHDSL_TCA_ES
SHDSL_TCA_SES
SHDSL_TCA_CRC
SHDSL_TCA_LOSW
SHDSL_TCA_UAS
VDSL_TCA_LOL
VDSL_TCA_LOF
VDSL_TCA_LOS
VDSL_TCA_LPR
VDSL_TCA_ES
VDSL_TCA_SES
Management Switch Card User's Guide
SEVERITY MSC ALC SLC VLC VOP IMA DESCRIPTION
INFO
X
INFO
X
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
INFO
The Severely Errored Seconds (<value>)
within 15 minutes for the atu(c or r) has
reached the threshold (<value>).
The UnAvailable Seconds (<value>)
within 15 minutes for the atu(c or r) has
reached the threshold (<value>).
X
The loop attenuation (<value>) of the
endpoint (unit address <value>-<side>-
wire pair <value>) reached or exceeded
the threshold (<value>).
X
The SNR margin (<value>) of the
endpoint (unit address <value>-<side>-
wire pair <value>) reached or dropped
below the threshold (<value>).
X
The error seconds (<value>) of the
endpoint (unit address <value>-<side>-
wire pair <value>) reached or exceeded
the threshold (<value>).
X
The severely errored seconds (<value>)
of the endpoint (unit address <value>-
<side>-wire pair <value>) reached or
exceeded the threshold (<value>).
X
The CRC anomalies (<value>) of the
endpoint (unit address <value>-<side>-
wire pair <value>) reached or exceeded
the threshold (<value>).
X
The Loss Of Sync Word seconds
(<value>) of the endpoint (unit address
<value>-<side>-wire pair <value>)
reached or exceeded the threshold
(<value>).
X
The UnAvailable Seconds (<value>) of
the endpoint (unit address <value>-
<side>-wire pair <value>) reached or
exceeded the threshold (<value>)
X
The Loss Of Link seconds (<value>)
within 15 minutes for the vtu(c or r) has
reached the threshold (<value>).
X
The Loss Of Frame seconds (<value>)
within 15 minutes for the vtu(c or r) has
reached the threshold (<value>).
X
The Loss Of Signal seconds (<value>)
within 15 minutes for the vtu(c or r) has
reached the threshold (<value>).
X
The Loss of Power (<value>) within 15
minutes for the vtu(c or r) has reached
the threshold (<value>).
X
The Error Seconds (<value>) within 15
minutes for the vtu(c or r) has reached
the threshold (<value>).
X
The Severely Errored Seconds (<value>)
within 15 minutes for the vtu(c or r) has
reached the threshold (<value>).
Chapter 5 Alarm Screens
155