Port Enet Ratelimit Command - ZyXEL Communications MSC1000G User Manual

Management switch card
Hide thumbs Also See for MSC1000G:
Table of Contents

Advertisement

29.10.13 port enet ratelimit Command

Syntax:
port enet ratelimit <slot-port> <rate-limit_profile>
This command sets the specified Ethernet port(s) to use a profile that limits egress and ingress
rates.
The following example sets port 13 on the ELC in slot 7 to use a rate limit profile named test.
ras>
port enet ratelimit 7-13 test
29.10.14 port enet show Command
Syntax:
port enet show <slot-port>
This command displays the settings for the specified Ethernet subscriber port(s). An example is
shown next for port 5 on the ELC in slot 4.
ras> port enet show 4-5
slot-port
pvid
priority
frametype
flowCtrl
ingress rate
egress rate
vlan setting:
vid
port
----- ----- -------- --------
76 4-5
29.10.15 port enet tls Commands
Syntax:
port enet tls disable <slot-port>
port enet tls enable <slot-port>
port enet tls set <slot-port> <svid> <spriority>
port enet tls show <slot-port>
where
<svid>
<spriority> =
Use these commands to configure Transparent LAN Service (TLS) settings on the Ethernet
subscriber port(s). Once you enable TLS, all packets will be added an extra "VLAN tag" (SPVID/
Management Switch Card User's Guide
:4-5
:76
:3
:all
:disable
:0 kbps
:0 kbps
adv
untag
fix
untag
=
Sets the service provider ID (from 1 to 4094) to add to received frames.
Sets the IEEE 802.1p priority level (from 0 to 7) for the service provider's VLAN
ID.
Chapter 29 port Commands
791

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc1024gMsc1224gMsc1024gbMsc1024gcMsc1224gb

Table of Contents