Monitoring The Device Using Cli; Event Log Configuration - Proxim ORiNOCO AP-800 Installation And Management Manual

Hide thumbs Also See for ORiNOCO AP-800:
Table of Contents

Advertisement

6.8 Monitoring the Device using CLI

To monitor the device, enter the following CLI commands.

6.8.1 Event Log Configuration

Enter the following commands to view and set priority for event logs.
To display the event log messages, use the following command:
AP-00:7D:09# show eventlog-messages
It displays the recent event log entries.
To clear the eventlog messages, see
ORiNOCO® AP-800 and AP-8000 Installation and Management Guide
AP-00:7D:09# configure
AP-00:7D:09(config)# monitor
AP-00:7D:09(config-mon)# ?
Possible completions:
eventlog
exit
station-disassociate
AP-00:7D:09(config-mon)# eventlog
AP-00:7D:09(config-mon-eventlog)# priority emergency
AP-00:7D:09(config-mon-eventlog)# reset no
AP-00:7D:09(config-mon-eventlog)#exit
AP-00:7D:09(config-mon)#exit
AP-00:7D:09(config)#exit
AP-00:7D:09# show eventlog
// EVENTLOG CONFIGURATION //
Priority
: emergency
Log Reset : no
Clear Statistics
Device Configuration, Management and Monitoring using CLI
Event Log Configuration
Exits Back to Global Configure Mode
Disassociate a station using its MAC ADDRESS