8.7.4 Client Computer Cannot Connect

1. Client computers should have the same Network Name (VAP SSID) and security settings as the device.
2. Network Names (VAP SSIDs) should be allocated and maintained by the Network Administrator.
3. For additional troubleshooting tips, see the documentation that comes with your client card.

8.7.5 Incorrect Device IP Address

1. The default IP address assignment mode is dynamic. The device contacts a DHCP server during boot-up. If the DHCP
server is not available on your network while the device is booting, then the fall back IP address (169.254.128.132) of
the device is used.
2. Use ScanTool, to find the current IP address of the device. Once you have the current IP address, use Web Interface or
CLI Interface to change the device IP settings, if necessary.
3. If you are using static IP address assignment, and cannot access the device over ethernet, refer to
Address using
Soft Reset to Factory Defaults
4. Perform the
Server on the network, the DHCP Server will assign an IP address automatically to the device.

8.7.6 HTTP Interface or Telnet Interface Does Not Work

1. Make sure you are using a compatible browser:
– Microsoft Internet Explorer 7.0 or later
– Mozilla Firefox 3.0 or later
2. Make sure you have the proper IP address of device. Enter the device IP address in the address bar of the browser, for
example http://169.254.128.132.
3. When the Enter Network Password window appears, enter the User Name and enter the HTTP password in the
Password field. The default HTTP username is admin and password is public.
4. Use CLI, to check the IP Access Table which can restrict access to Telnet and HTTP.

8.7.7 Telnet CLI Does Not Work

1. Make sure you have the proper IP address. Enter the device IP address in the Telnet connection dialog, from a DOS
prompt: C:\> telnet <Device IP Address>
2. Use HTTP, to check the IP Access Table which can restrict access to Telnet and HTTP.
: Please enable Telnet in Vista or Windows 7 as it is by default disabled.
ORiNOCO® AP-800 and AP-8000 Installation and Management Guide
CLI.
procedure. This will reset the device to dynamic mode. If there is a DHCP
Troubleshooting