2. To add an entry, click Add. The Static MAC Address Filter Add Row screen appears.
3. Configure the following parameters:
Wired MAC Address: Specifies the MAC address of the device on the wired network that is restricted from
communicating with a device on the wireless network. To configure, enter a Wired MAC Address.
Wired MAC Mask: Specifies the range of the wired MAC addresses to which the filter is applied. To configure,
enter a Wired MAC Mask.
Wireless MAC Address: Specifies the MAC address of the device on the wireless network that is restricted from
communicating with a device on the wired network. To configure, enter a Wireless MAC Address.
Wireless MAC Mask: Specifies the range of the wireless MAC addresses to which the filter is applied. To
configure, enter a Wireless MAC Mask.
Comment: Specifies the comment associated with Static MAC Filter table entry.
Status: Specifies the status of the newly created filter. By default, it is enabled. To disable, click Disable from the
Status box. Filters are applied between the wired and wireless devices, only when the status is enabled.
4. Click Add, to save the configured entry.
:
• The maximum number of Static MAC Filters that can be added are 200.
• Wired and Wireless MAC Address cannot have broadcast and multicast MAC address.
ORiNOCO® AP-800 and AP-8000 Installation and Management Guide
Figure 3-40 Static MAC Address Filters
Figure 3-41 Static MAC Address Filter - Add Entries
Device Configuration Using Web Interface