2. Configure the following parameters:
Enable SNTP Status: Specifies the status of the SNTP feature on the device. Select the Enable SNTP Status
checkbox to synchronize the date and time of the device with the SNTP time server.
Primary Server IP Address / Domain Name: Specifies the host name or the IP address of the primary SNTP
server. To configure, enter the Primary Server IP Address/Domain Name.
Secondary Server IP Address / Domain Name: Specifies the host name or the IP address of the secondary SNTP
server. To configure, enter the Secondary Server IP Address/Domain Name.
Time zone: Specifies the time zone set for the SNTP. To configure, select the desired time zone from the drop
down menu.
Day Light Saving Time: Specifies the number of hours adjusted for the Daylight Saving Time. To configure,
select the desired Day Light Saving Time from the drop down menu.
Current Date / Time: Specifies a read-only parameter which displays the system current date and time. If SNTP is
not enabled, the current date and time are automatically generated from the local system. If SNTP is enabled, it
displays the time, which the device has obtained from the SNTP server.
3. Click OK.
: Configure the parameters, namely, Primary Server IP Address / Domain Name, Secondary Server IP Address / Domain
Name, Time zone and Day Light Saving Time, only when the SNTP status is enabled.

4.5 Access Control

The Management Access Control feature allows you to manage the device from the specified host.
To access this feature, do the following:
1. Navigate to MANAGEMENT > Access Control. The Management Access Control Table screen appears.
2. The Management Access Control Table contains the following information:
Access Table Status: Specifies the status of the Access Control on the AP device. By default, the Management
Access Control is disabled on the device. To enable it, select Enable from the drop down menu.
IP Address: Specifies the IP address of the machine that would manage the device.
Entry Status: Specifies the status of the added entry. To configure, select Enable or Disable from the drop down
menu.
3. Click OK and reboot the device, if you have changed the values in the Access Control Table.
ORiNOCO® AP-800 and AP-8000 Installation and Management Guide
Figure 4-21 Management Access Control Table