7.3 Viewing the MIB Objects

1. After configuring the pre-requisite information, load the MIB file.
2. Navigate to Proxim under the private node.
To view all the objects, right-click and select Walk. This will display all the default and configured objects.
To view a particular object, select a particular object, right-click and click Get. This will display the selected configured
object.

7.4 Configuring the MIB Objects

7.4.1 To Configure the Scalar Objects

1. Select the object, right-click and click Set. This will display the existing configured values.
2. To make changes to the existing value, double-click the object. This displays the list of values for configuration. Select the
desired values and click Ok.
3. Click Execute to store the changes in the temporary buffer and proceed to SysMgmtCfgCommit table to Commit the
changes.

7.4.2 To Configure the Tabular Objects

1. Select the object, right-click and click Get Table. This displays the Table List.
2. From the menu, click Set and drag the table entry for which you want to make the changes to the Set window.
: You can configure table by configuring each entry that is available for the table or update the entire table as a
single entry.
3. Select the table, right-click, and click Set.
4. In the Set window, to add a row for a table, enter "0" and this will automatically create a row for a particular table.
5. Add the required parameters and configure those parameters.
6. Click Execute and proceed to SysMgmtCfgCommit table to Commit the changes.

7.4.3 To apply the changes to the flash memory

1. Navigate to deviceMgmt > SysMgmtCfgCommit, right-click and click Set.
2. Set the value as 1 and click OK.
3. Click Execute, this would configure the new value to the flash memory.