Gigabit Poe Injector (Not Supplied); The Device Does Not Work; There Is No Data Link; Overload Indications - Proxim ORiNOCO AP-800 Installation And Management Manual

Hide thumbs Also See for ORiNOCO AP-800:
Table of Contents

Advertisement

8.5 Gigabit PoE Injector (Not supplied)

8.5.1 The Device Does Not Work

1. Make sure that you are using a standard UTP Category 5/Category6 cable.
2. Try a different port on the same PoE Injector hub (remember to move the input port accordingly) – if it works then
there is a problem in the previous RJ45 port or a bad RJ45 port connection.
3. Try to connect the device to a different PoE Injector hub.
4. Try using a different ethernet cable – if it works, there is probably a fault in the cable or its connection.
5. Check the power plug and hub.
6. If the ethernet link goes down, check the cable, cable type, switch and hub.

8.5.2 There Is No Data Link

1. Verify that the indicator on the device port is "ON."
2. Verify that the PoE Injector hub is properly connected to the ethernet port of the device.
3. Verify that the ethernet cable is Category 5 or better and is less than 100 meters (approximately 325 feet) in length
from the ethernet port of the device to the PoE.
4. Try to connect a different device to the same port on the PoE Injector hub – if it works and a link is established then
there is probably a fault in the data link of the device.
5. Try to re-connect the cable to a different output port (remember to move the input port accordingly) – if it works then
there is a fault probably in the output or input port of the PoE Injector hub or a bad RJ45 connection.

8.5.3 Overload Indications

1. Connect the device to a PoE Injector.
2. Ensure that there is no short over on any of the connected cables.
3. Move the device into a different output port (remember to move the input port accordingly) - if it works then there is
a fault probably in the previous RJ45 port or bad RJ45 port connection.

8.6 Connectivity Issues

Connectivity issues include any problem that prevents you from powering up or connecting to the device.

8.6.1 Device Does Not Boot - No LED Activity

1. Make sure your power source is ON.
2. Make sure all the cables to the device are connected properly.
3. If you are using Gigabit Ethernet PoE, make sure you are using a Category 5/Category 6, foiled, twisted pair cable to
power the device.

8.6.2 Ethernet Link Does Not Work

Check the ethernet LED. The color of the Ethernet LED indicates the speed of the Ethernet traffic:
RED
GREEN
OFF
ORiNOCO® AP-800 and AP-8000 Installation and Management Guide
: 100 Mbps
: 1000 Mbps
: No link is available or Ethernet is not connected