4. If WEP or WPA-PSK/WPA2-PSK Security mechanisms are used, then ensure that pass-phrase configured in security
profile and the client are the same.
5. If WPA or WPA2 Security mechanisms are used, then ensure the EAP settings are proper in the client and the RADIUS
server.

8.7.12 VLAN Operation Issues

8.7.12.1 Verifying Proper Operation of the VLAN Feature
The correct VLAN configuration can be verified by using ping command in both wired and wireless hosts from both sides of
the device and the network switch. Traffic can be "sniffed" on the wired (ethernet), if configured. Bridge frames generated by
wireless clients and viewed on one of the backbones should contain IEEE 802.1Q compliant VLAN headers or tags. The VLAN
ID in the headers should correspond to one of the VLAN User IDs configured for the device.
8.7.12.2 VLAN Workgroups
The correct VLAN assignment can be verified by pinging the device to ensure connectivity, by pinging the switch to ensure
VLAN properties, and by pinging hosts past the switch to confirm the switch is functional. Ultimately, traffic can be "sniffed"
on the ethernet using third-party packages. Most problems can be avoided by ensuring that 802.1Q compliant VLAN tags
containing the proper VLAN ID have been inserted in the bridged frames. The VLAN ID in the header should correspond to the
user's assigned network name.
Forced Reload
The
What if network traffic is being directed to a non-existent host?
All sessions are disconnected, traffic is lost, and a
Workaround: You can configure the switch to mimic the non-existent host.
I have just configured the Management ID and now I can't manage the device?
Check to ensure your password is correct. If your password is incorrect or all inbound packets do NOT have the correct
Forced Reload
tag, then a

8.8 Recovery Procedures

8.8.1 Soft Reset to Factory Defaults

Use this procedure to reset the network configuration values, including the Password, IP Address, and Subnet Mask. This
procedure resets configuration settings, but does not change the current device Image.
To use this procedure, in the web interface navigate to MANAGEMENT > Reset to Factory.
The DHCP Server gets the default IP address (169.254.128.132) for the device. You can change the IP address using Web
Interface or CLI. If you do not have access to the HTTP or CLI interfaces, use
: If you are not able to access and configure the device using web interface, then enter the username and password
as reload, in terminal emulator (serial) interface, after the device is initialized. This soft reset procedure will set the
device to factory defaults.
ORiNOCO® AP-800 and AP-8000 Installation and Management Guide
procedure disconnects all the users and resets all values to factory defaults.
is necessary.
Forced Reload
is necessary.
Hard Reset to Factory Defaults
Troubleshooting
procedure.