4. Open your terminal emulator program and set the following connection properties:
Com Port: COM1, COM2 and so on, depending on your computer
Baud Rate: 115200
Data Bits: 8
Stop Bits: 1
Flow Control: None
Parity: None
5. The terminal display shows Power On Self Tests (POST) activity. After approximately 30 seconds, a message indicates:
Starting ScanTool interface, press any key to enter CLI 5". After this message appears, press any key. Now the
bootloader prompt appears as below:
Bootloader=>
: Optionally, you can enable Send line ends with line feeds (CTRL+F) under File > Properties > Settings >
ASCII Setup, to allow the Terminal Emulator program send a line return at the end of each line of code.
6. Enter the following commands:
Bootloader=> show (to view configuration parameters and values)
Bootloader=> set ipaddr <Access Point IP Address>
Bootloader=> set serverip <TFTP Server IP Address>
Bootloader=> set filename <Device Image File Name, including file extension>
Bootloader=> set gatewayip <Gateway Ip Address>
Bootloader=> set netmask <Network Mask>
Bootloader=> set ipaddrtype static
Bootloader=> show (to confirm your new settings)
Bootloader=> reboot
Example:
Bootloader=> show
Bootloader=> set ipaddr 169.254.128.132
Bootloader=> set serverip 169.254.128.133
Bootloader=> set filename apimage_proxim.sei
Bootloader=> set gatewayip 169.254.128.133
Bootloader=> set netmask 255.255.255.0
Bootloader=> set ipaddrtype static
Bootloader=> show
Bootloader=> save
Bootloader=> reboot
The device will reboot and then download the image file.
7. When the download process is complete, configure the device.

8.8.5 Setting IP Address using Serial Port

Use the following procedure to set an IP address for the device by using the CLI. The Network Administrator typically provides
the device IP address.
8.8.5.1 Hardware and Software Requirements
Standard serial (RS-232) cable (not included in the Product Package).
ASCII Terminal software.