Table 231: Diagnostics Via Signal Quality Leds; Table 232: Signal Quality Meaning - WAGO 750-8207 Manual

Pfc200 cs 2eth rs 3g plc - controller pfc200
Table of Contents

Advertisement

326 Diagnostics

Table 231: Diagnostics via Signal Quality LEDs

(S1)
OFF
Yellow
Green
Green
Green
Green
Green

Table 232: Signal Quality Meaning

Signal quality
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Depending on the mobile network load and limitations set by the mobile network
service provider, the actual data rate may be slower than the signal quality allows
at the time.
Manual
Draft version 1.2.1 from 2017-09-13, valid from FW Version 02.06.20(09)
Status of signal quality LEDs
▐█
(S2)
(S3)
OFF
OFF
OFF
OFF
OFF
OFF
Green
OFF
Green
Green
Green
Green
Green
Green
UMTS
Only UMTS, probable
connection failure
HDSPA possible, instable
connection
HDSPA possible, no weather
reserve
HDSPA, stabile connection
HDSPA, maximum data rate
7.2 Mbit/s
HSPA+ possible (if available)
WAGO-I/O-SYSTEM 750
750-8207 PFC200 CS 2ETH RS 3G
██
▐██
(S4)
(S5)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Green
OFF
Green
Green
Explanation
Only GSM, probable
connection failure
GPRS, very slow data
connection
GPRS, stabile data connection,
maximum data rate (54 kbit/s)
EDGE, stabile, very slow data
connection possible
EDGE, maximum data rate
(220 kBit/s)
E-EDGE possible (up to
1 Mbit/s)
Signal quality
No network
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6