Step 2 - Storing the revolution counter setting with the FlexPendant
This procedure details the second step when updating the revolution counter; storing the
revolution counter setting with the FlexPendant (RobotWare 5.0).
3HAC022032-001 Revision: E
Action
1. On the ABB menu, tap Calibration.
All mechanical units connected to the system are shown along with their calibration
status.
2. Tap the mechanical unit in question.
A screen is displayed: tap Rev. Counters.
en0400000771
3. Tap Update Revolution Counters....
A dialog box is displayed, warning that updating the revolution counters may change
programmed robot positions:
•
Tap Yes to update the revolution counters.
•
Tap No to cancel updating the revolution counters.
Tapping Yes displays the axis selection window.
4. Select the axis to have its revolution counter updated by:
•
Ticking in the box to the left
•
Tapping Select all to update all axes.
Then tap Update.
5. A dialog box is displayed, warning that the updating operation cannot be undone:
•
Tap Update to proceed with updating the revolution counters.
•
Tap Cancel to cancel updating the revolution counters.
Tapping Update updates the ticked revolution counters and removes the tick from the
list of axes.
5 Calibration information
5.5. Updating revolution counters
Continues on next page
Continued