Mounting Instructions For Seals - ABB IRB 4400 - 45 Product Manual

Articulated robot
Table of Contents

Advertisement

4 Repair

4.2.3. Mounting instructions for seals

4.2.3. Mounting instructions for seals
General
This sections details how to mount different types of seals to the robot.
Equipment
Equipment, etc.
Grease
Rotating seals
The procedure below details how to fit rotating seals.
Please observe the following before commencing any assembly of seals:
114
Art. no.
3HAB 3537-1
Protect the sealing surfaces during transport and mounting.
Keep the seal in its original wrappings or protect it well before actual mounting.
The fitting of seals and gears must be carried out on clean workbenches.
Use a protective sleeve for the sealing lip during mounting, when sliding over threads,
keyways, etc.
Action
1. Check the seal to ensure that:
the seal is of the correct type (provided with cutting
edge).
there is no damage to the sealing edge (feel with a
fingernail).
2. Inspect the sealing surface before mounting. If scratches or
damage are found, the seal must be replaced, as it may
result in future leakage.
3. Lubricate the seal with grease just before fitting. (Not too
early as there is a risk of dirt and foreign particles adhering
to the seal.)
Fill the space between the dust tongue and sealing lip to 2/
3 with grease. The rubber coated external diameter must
also be greased, unless otherwise specified.
4. Mount the seal correctly with a mounting tool.
Never hammer directly on the seal as this may result in
leakage.
Note
Used to lubricate the seals.
Note
Art. no. is specified in
Equipment on page
Continues on next page
3HAC022032-001 Revision: E