4 Repair
4.4.2. Replacement of wrist unit
Continued
Refitting, wrist unit IRB 4400/L10
The procedure below details how to refit the wrist unit to robot version IRB 4400/L10.
This component includes a complete unit comprising motors and gearboxes. It is a
replacement unit of complex design and should not normally be serviced on-site. Instead it
should be sent to ABB for service etc.
ABB recommends its customers carry out only the following servicing/repair work on this
unit.
142
Action
1.
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot!
For Foundry Prime robots: Do not turn off
the air pressure to motors and SMB.
2. Lubricate and fit the o-ring to the wrist unit. Part no. is specified in
3. Move the upper arm to a vertical position,
wrist side pointing upwards.
4. Refit the wrist unit. Do not tighten the
attachment screws!
5. Release the brakes on axes 5 and 6 (one at
a time) and fit the measuring tool at the rear
of the motor.
6. Push the wrist to locate the smallest play.
Note/Illustration
Required
equipment on page
138.
Shown in the figure
Location of wrist
unit on page
138.
Art. no. is specified in
Required
equipment on page
138.
Adjustment of play is detailed in
section
Refitting of motors axis 5 and
6.
xx0300000153
Upper arm seen from front
A: Gears on drive shaft
B: Gears on wrist
Continues on next page