IQ13 Partial Blank Image (Not Periodic) RAP
Use this RAP when the printed sheets have blank areas, that do not form a regular pattern.
Ensure the
IQ1 Image Quality Entry RAP
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Perform the following:
1.
(3635 only) Check the wiring between the LSU and CN24 on the
2.
(3550 only) Check the wiring between the LSU and CN17 on the
3.
Install a new print cartridge,
PL 9.10 Item
Image Quality
IQ13, IQ14
is performed before starting this RAP.
Main
PWB.
Main
PWB.
1.
IQ14 Partial Blank Image (Periodic) RAP
Use this RAP when the printed sheets have blank areas that form a regular, or repeated,
defect.
Ensure the
IQ1 Image Quality Entry RAP
Procedure
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Perform the following:
1.
Measure the distance between the image and the defect. Refer to
the possible cause of the defect.
Defect distance
Roll
95mm (3.7 inches)
Xerographic drum
38mm (1.5 inches)
Charge roll
45mm (1.8 inches)
Supply roll
47mm (1.9 inches)
Transfer roll
89mm (3.5 inches)
Heat roll
51mm (2 inches)
Pressure roll 1
64mm (2.5 inches)
Pressure roll 2
2.
Install new components as necessary.
April 2010
3-16
is performed before starting this RAP.
WARNING
Table 1
Table 1 Defect distance
Component
Parts List Ref.
Print cartridge
PL 9.10 Item 1
Print cartridge
PL 9.10 Item 1
Print cartridge
PL 9.10 Item 1
Transfer roll
PL 9.10 Item 2
Fuser assembly
PL 10.15 Item 1
Fuser assembly
PL 10.15 Item 2
Fuser assembly
PL 10.15 Item 3
Phaser 3635MFP/WorkCentre 3550