1.4.1 Configuring the Time-Range

The process of configuring a time-range includes the steps of configuring the
hour-minute range, date ranges and period range. The hour-minute range is expressed
in the units of minute, hour. Date range is expressed in the units of minute, hour, date,
month and year. The periodic time range is expressed in the day of the week.
You can use the following command to set the time range by performing the following
configuration in the system view.
Table 1-19 Setting the absolute time range
Operation
Set
absolute
range
Delete
absolute
range
When the start-time and end-time are not configured, it will be all the time for one day.
The end time shall be later than the start time.
When end-time end-date is not configured, it will be all the time from now to the date
which can be displayed by the system. The end time shall be later than the start time.

1.4.2 Defining and Applying Flow Template

I. Defining Flow Template
Flow template defines useful information used in flow classification. For example, a
template defines a quadruple: source and destination IP, source and destination TCP
ports, and then only those traffic rules including all these elements can be sent to target
hardware and referenced for such QoS functions as packet filtering, traffic policing,
priority re-labeling. Otherwise, the rules cannot be activated on the hardware and
referenced.
Please perform the following configurations in system view.
Table 1-20 Defining flow template
Operation
Define flow template
Delete flow template
Note that the sum of all elements should be less than 16 bytes in length. The following
table lists the length of the elements involved.
the
time-range time-name { start-time to end-time days-of-the-week
time
[ from start-time start-date ] [ to end-time end-date ] | from
start-time start-date [ to end-time end-date ] }
the
undo
time-range
time
days-of-the-week [ from start-time start-date ] [ to end-time
end-date ] | from start-time start-date [ to end-time end-date ] ]
flow-template user-defined template-info
undo flow-template user-defined
Huawei Technologies Proprietary
Command
time-name
[
Command
1-18
Chapter 1 ACL Configuration
start-time
to
end-time

Hide quick links: