Huawei Quidway S3500 Series Operation Manual page 658

Hide thumbs Also See for Quidway S3500 Series:
Table of Contents

Advertisement

Operation Manual - Auto Detecting
Quidway S3500 Series Ethernet Switches
III. Configuration procedure
# Enter system view.
<Quidway> system-view
# Create a detecting group numbered 10 and enter its view.
[Quidway] detect-group 10
# Specify to detect the interface with an IP address of 10.1.1.4 and take the interface
with an IP address of 192.168.1.2 as the next hop, and set the number of this operation
to 1.
[Quidway-detect-group-10]
192.168.1.2
# Specify to detect the interface with an IP address of 192.168.2.2 and set the number
of this operation to 1.
[Quidway-detect-group-10] detect-list 2 ip address 192.168.2.2
# Specify to return reachable as the detecting result if one of the two interfaces is
detected to be reachable.
[Quidway-detect-group-10] option or
# Set the detecting interval to 60 seconds.
[Quidway-detect-group-10] timer loop 60
# Set the maximum retries during a detection to 3.
[Quidway-detect-group-10] retry 3
# Set the detecting timeout time to 3 seconds.
[Quidway-detect-group-10] timer wait 3
[Quidway-detect-group-10] quit
# Display configurations of detecting group 10.
[Quidway] display detect-group 10
detect-list
Huawei Technologies Proprietary
1-3
Chapter 1 Configuring Auto Detecting
1
ip