[Switch C] rip
[Switch C-rip] network 117.102.0.0
[Switch C-rip] network 110.11.2.0

3.5 RIP Fault Diagnosis and Troubleshooting

Fault: The S3500 Series Ethernet Switches cannot receive the update packets when
the physical connection to the peer routing device is normal.
Troubleshooting: RIP does not operate on the corresponding interface (for example,
the undo rip work command is executed) or this interface is not enabled through the
network command. The peer routing device is configured to be in the multicast mode
(for example, the rip version 2 multicast command is executed) but the multicast
mode has not been configured on the corresponding interface of the local Ethernet
Switch.