Chapter 4 User Interface Configuration

4.1 User Interface Overview
User interface configuration is another way provided by the switch to configure and
manage the port data.
S3500 series switches support the following configuration methods:
Local configuration via the Console port
Local and remote configuration through Telnet or SSH on Ethernet port
Remote configuration through dial with modem via the Console port.
According to the above-mentioned configuration methods, there are two types of user
interfaces:
AUX user interface
AUX user interface is used to log in the switch via the Console port. A switch can only
have one AUX user interface.
VTY user interface
VTY user interface is used to telnet the switch. A switch can have up to five VTY user
interface.
Note:
For Quidway series switches, AUX port and Console port are the same one. There is
only the type of AUX user interface.
User interface is numbered in the following two ways: absolute number and relative
number.
1)
Absolute number, following the rules below.
AUX user interface is numbered as the first interface designated as user interface
0.
VTY is numbered after AUX user interface. The absolute number of the first VTY is
incremented by 1 than the AUX user interface number.
2)
Relative number, represented by "+ number" assigned to each type of user
interface. It follows the rules below:
Number of AUX user interface: AUX 0.
Number of VTY: The first VTY interface is designated as VTY 0, the second one is
designated as VTY 1, and so on.