Measurement Results Output Format

8-5

Measurement Results Output Format

Note The output of data after measurement is performed in Run
230
Measurement results are output in ASCII in order from the
smallest output number to the largest.
The measurement results are output in the normal format
even in Menu operation mode.
The amount of output data will depend on the number of digits
in the measurement values.
[<Measurement_results_for_data_0>],
[<Measurement_results_for_data_1>],
[<Measurement_results_for_data_2>],
[<Measurement_results_for_data_3>],
[<Measurement_results_for_data_4>],
[<Measurement_results_for_data_5>],
[<Measurement_results_for_data_6>],
[<Measurement_results_for_data_7>]
• Outputs are made in decimal, with a maximum of 7 digits
before the decimal point and 3 digits after. The number of
digits before the decimal point that are actually displayed
will vary according to the measurement value but the
number of digits after the decimal point is fixed to 3.
• Calibrated values are output. Output values will be in the
range –9,999,999.999 to 9,999,999.999. If the measure-
ment value is less than –9,999,999.999, then
–9,999,999.999 will be output. If the measurement value
is greater than 9,999,999.999, then 9,999,999.999 will be
output.
• When a judgement is set, either 0 (OK) or –1 (NG) will be
output.
mode will continue until all of the data has been output,
even if the mode is changed. Data output will not be inter-
rupted.
Section 8-5