VDC Sequence Control
VEHICLE DYNAMICS CONTROL (VDC)
4. VDC Sequence Control
A: OPERATION
1) While the VDC sequence control is performed,
the operation of the hydraulic unit can be checked
using the brake tester or pressure gauge after the
hydraulic unit solenoid valve is operated.
2) VDC sequence control can be started by Subaru
Select Monitor.
1. VDC SEQUENCE CONTROL WITH SUB-
ARU SELECT MONITOR
NOTE:
In the event of any trouble, the sequence control
does not operate.
1) Connect the Subaru Select Monitor to data link
connector under the driver's side instrument panel
lower cover.
2) Turn the ignition switch to ON.
3) Set the Subaru Select Monitor power switch to
ON.
4) Set the Subaru Select Monitor to "Brake Control"
mode.
5) When the "VDC Inspection Mode" is selected
from the "Function check sequence" menu, the
"VDC sequence control" will start.
6) Since "Press the [YES] key" is displayed, press
the YES key.
7) Operation points will be displayed on the Subaru
Select Monitor.