11) Tighten the bolts which hold the hose bracket.
Tightening torque:
10 N
m (1.0 kgf-m, 7.4 ft-lb)
(1) Hose ASSY
(2) Hose bracket
12) Install the air intake duct<Ref. to IN(H4SO 2.0)-
8, INSTALLATION, Air Intake Duct.>
13) Connect the ground cable to battery.
14) Feed the specified fluid.
CAUTION:
Never start the engine before feeding the fluid;
otherwise vane pump might be seized up.
15) Finally, check clearance between pipes or hos-
es as shown in the figure indicated in "General Di-
agnostic Table". <Ref. to PS-96, INSPECTION OF
CLEARANCE, INSPECTION, General Diagnostic
Table.>