Labeling Jacks - Avaya PARTNER Installation And Use Manual

Advanced communications system
Hide thumbs Also See for PARTNER:
Table of Contents

Advertisement

4. In the other slots, from left to right, first install
the T1 module or 1600 DSL module, then the
012E, 308EC, or 206 modules, followed by the
400 or 200 modules and/or a PARTNER
Messaging or PARTNER MAIL VS module.
Align the module carefully in the appropriate
slot. For proper engagement of the connectors,
the module must be inserted straight into the
carrier (see
Figure
properly seated, firmly push the center of the
module until the connectors on the module lock
into place. A slight click indicates the
connectors are engaged.
If you use a T1 module or a 1600 DSL module, it must be in the first slot on the left. The
012E, 308EC, and 206 modules must be to the left of any 400 and 200 module.
PARTNER ACS Release 7.0 supports Endeavor telephones when an Endeavor 362EC
module is installed in the carrier. Install the Endeavor 362EC module(s) to the right of the
T1 module or 1600 DSL module, if one is installed, and to the left of all 400 and 200
modules.
In Release 7.0, the system extension maximum is 48. However, in some configurations,
the 012E module and/or the PARTNER Messaging module will physically permit more
than 48 stations to be installed in the 5-slot carrier. In these configurations, only station
ports and voice messaging ports up to 48 will function. Station ports and voice messaging
ports above 48 will not function with ETR or T/R telephones because they are outside the
PARTNER ACS dial plan.
CAUTION:
Do not force the module. Use the carrier shelf as a reference and do not tilt, slant, or
rotate the module. If the module does not insert easily, remove it, clear any
obstruction, and reinsert it.

Labeling Jacks

After you have mounted the control unit on the wall, you must label the line and extension jacks.
The line jacks are on the top of the modules, and the extension jacks on the bottom
(see
Figure
2-11).
2-10). Once the module is
Figure 2-10. Inserting a Module
Carrier Shelf
YES
2
Installing the Control Unit
Installation
Carrier Shelf
NO
2-9

Advertisement