For information about the modules that support bridged IP interfaces on the E120
and E320 routers:

Interface Specifiers

The configuration task examples in this chapter use the slot/port[.subinterface ] format
to specify the ATM physical interface on which you want to configure bridged IP.
However, the interface specifier format that you use depends on the router that you
are using.
For ERX7xx models, ERX14xx models, and ERX310 router, use the
slot/port[.subinterface ] format. For example, the following command specifies
ATM 1483 subinterface 10 on slot 0, port 1 of an ERX7xx model, ERX14xx model,
or ERX310 router.
For E120 and E320 routers, use the slot/adapter/port[.subinterface ] format, which
includes an identifier for the bay in which the I/O adapter (IOA) resides. In the
software, adapter 0 identifies the right IOA bay (E120 router) and the upper IOA bay
(E320 router); adapter 1 identifies the left IOA bay (E120 router) and the lower IOA
bay (E320 router). For example, the following command specifies ATM 1483
subinterface 20 on slot 5, adapter 0, port 0 of an E320 router.
For more information about supported interface types and specifiers on E Series
routers, see Interface Types and Specifiers in JUNOSe Command Reference Guide.

References

For more information about bridged IP, consult RFC 2684 Multiprotocol
Encapsulation over ATM Adaptation Layer 5 (September 1999). Note that RFC 2684
obsoletes RFC 1483.

Before You Configure Bridged IP

Before you configure bridged IP on an ATM interface, verify that:
See E120 and E320 Module Guide, Table 1, Modules and IOAs for detailed module
specifications.
See E120 and E320 Module Guide, Appendix A, IOA Protocol Support for information
about the modules that support bridged IP.
host1(config)#interface atm 0/1.10
host1(config)#interface atm 5/0/0.20
You have correctly installed a module that supports bridged IP. For information,
see ERX Module Guide, Appendix A, Module Protocol Support (on ERX7xx models,
ERX14xx models, and the ERX310 router) or E120 and E320 Module Guide,
Appendix A, IOA Protocol Support (on the E120 or the E320 router).
Each configured line can transmit data to and receive data from your switch
connections.
Chapter 11: Configuring Bridged IP
389