Configuring Frame Relay

Configure a Frame Relay interface by entering Interface Configuration mode. The
procedure that follows is an example of a Frame Relay configuration on a serial
interface. All tasks are mandatory unless otherwise noted.
To configure a Frame Relay interface:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
From Configuration mode, enter the physical interface on which you want to
configure Frame Relay.
host1(config)#interface serial 3/1:2/1
Select Frame Relay as the encapsulation method for the interface.
host1(config-if)#encapsulation frame-relay ietf
(Optional) Assign a text description or an alias to the major interface.
host1(config-if)#frame-relay description boston01
(Optional) Enable SNMP link status processing on the major interface.
host1(config-if)#snmp trap frame-relay link-status
Configure the interface as a DTE, DCE, or NNI.
host1(config-if)#frame-relay intf-type dte
Configure the LMI type.
host1(config-if)#frame-relay lmi-type ansi
(Optional) Configure Frame Relay counters and timers.
host1(config-if)#frame-relay lmi-n391dte 20
Configure the cyclic redundancy check (CRC).
host1(config-if)#crc 32
Create a subinterface.
host1(config)#interface serial 3/1:2/1.1
(Optional) Assign a text description or an alias to the subinterface.
host1(config-subif)#frame-relay description westford011
(Optional) Enable SNMP link status processing on the subinterface.
host1(config-subif)#snmp trap frame-relay link-status
Add a circuit to a subinterface.
host1(config-subif)#frame-relay interface-dlci 17 ietf
Chapter 2: Configuring Frame Relay

Configuring Frame Relay

111