For the DCE:
Enquiries received Total number of LMI status enquiries received by
the DCE on this interface
Enquiry responses sent Total number of LMI status responses sent by
the DCE on this interface
Full enquiry responses sent Total number of LMI full-status responses
sent by the DCE on this interface
Async updates sent Total number of LMI asynchronous updates sent
by the DCE on this interface
Unknown messages received Total number of unknown LMI messages
received on this interface
Loss of sequencing detected Total number of times a loss of sequencing
in received LMI messages was detected by the DCE on this interface
No response timeouts Total number of times a timeout occurred without
receiving a status inquiry from the DTE on this interface
Last sequence number sent Last sequence number sent on this interface
Last sequence number received Last sequence number received on
this interface
Example
host1#show frame-relay lmi
LMI information for frame relay NNI interface 3/2:1/1
DTE Parameter N391 is 6, N392 is 3, N393 is 4, T391 is 10
DCE Parameter N392 is 2, N393 is 2, T392 is 15
Configured LMI type is ANSI, status is up
Time since last status change 01:21:14
Enquiries received: 1232
Full enquiries received: 207
Enquiry responses sent: 1232
Full enquiry responses sent: 207
Async updates sent: 0
Unknown messages received: 0
Loss of sequencing detected: 2
No response timeouts: 0
Last sequence number sent: 0
Last sequence number received: 0
Unknown messages received: 0
Loss of sequencing detected: 2
LMI information for frame relay DCE interface 3/2:2/1
Parameter N392 is 2, N393 is 2, T392 is 15
Configured LMI type is ANSI, status is up
Time since last status change 03:06:22
Enquiries received: 1233
Full enquiries received: 207
Enquiry responses sent: 1233
Full enquiry responses sent: 207
Async updates sent: 0
Chapter 2: Configuring Frame Relay
Monitoring Frame Relay
127