Interval (Ex Series Switch Only); Level (Ex Series Switch Only) - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos

interval (EX Series Switch Only)

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation

level (EX Series Switch Only)

Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
4098
®
OS for EX Series Ethernet Switches, Release 10.4
interval (10m | 10s | 1m | 1s | 100ms | 10ms);
[edit protocols oam ethernet connectivity-fault-management maintenance-domain
domain-name maintenance-association ma-name continuity-check]
Statement introduced in Junos OS Release 10.2 for EX Series switches.
Configure the time between continuity check messages.
—10 minutes.
10m
10s
—10 seconds.
—1 minute.
1m
1s
—1 second.
—100 milliseconds.
100ms
10ms
—10 milliseconds.
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring Ethernet OAM Connectivity Fault Management (CLI Procedure) on page 4082
Junos OS Network Interfaces Configuration Guide
level number;
[edit protocols oam ethernet connectivity-fault-management maintenance-domain
domain-name]
Statement introduced in Junos OS Release 10.2 for EX Series switches.
Configure a number to be used in CFM messages to identify the maintenance association.
—Number used to identify the maintenance domain to which the CFM message
number
belongs.
Range: 0 through 7
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring Ethernet OAM Connectivity Fault Management (CLI Procedure) on page 4082
Junos OS Network Interfaces Configuration Guide
Copyright © 2010, Juniper Networks, Inc.