frame-error
Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
frame-period
Syntax
Hierarchy Level
Release Information
Description
Options
Required Privilege
Level
Related
Documentation
Copyright © 2010, Juniper Networks, Inc.
frame-error count;
[edit protocols oam ethernet link-fault-management event link-event-rate],
[edit protocols oam ethernet link-fault-management interface interface-name
event-thresholds]
Statement introduced in Junos OS Release 9.4 for EX Series switches.
Configure the threshold value for sending frame error events or taking the action specified
in the action profile.
Frame errors occur on the underlying physical layer. The threshold is reached when the
number of frame errors reaches the configured value.
count—Threshold count in seconds for frame error events.
Range: 1 through 100 seconds
Default: 1 second
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring Ethernet OAM Link Fault Management (CLI Procedure) on page 4043
frame-period count;
[edit protocols oam ethernet link-fault-management event link-event-rate],
[edit protocols oam ethernet link-fault-management interface interface-name
event-thresholds]
Statement introduced in Junos OS Release 9.4 for EX Series switches.
Configure the number of frame errors within the last N frames that has exceeded a
threshold.
Frame errors occur on the underlying physical layer. The threshold is reached when the
number of frame errors reaches the configured value.
count—Threshold count in seconds for frame error events.
Range: 1 through 100 seconds
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Configuring Ethernet OAM Link Fault Management (CLI Procedure) on page 4043
Chapter 142: Ethernet OAM Link Fault Management