Configuring A Connectivity Fault Management Action Profile - Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual

For ex series ethernet switches
Table of Contents

Advertisement

Copyright © 2010, Juniper Networks, Inc.
Specify an ID for the MEP. The value can be from 1 through 8191.
1.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain domain-name maintenance-association ma-name]
user@switch# set mep mep-id]
Enable maintenance endpoint automatic discovery if you want to have the MEP accept
2.
continuity check messages (CCMs) from all remote MEPs of the same maintenance
association:
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain domain-name maintenance-association ma-name mep mep-id
user@switch# set auto-discovery
You can specify that CFM packets (CCMs) be transmitted only in one direction for the
3.
MEP, that is, the direction be set as
(not into) the interface configured on this MEP.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain domain-name maintenance-association ma-name mep mep-id]
user@switch# set direction down
Specify the logical interface to which the MEP is attached. It can be either an access
4.
interface or a trunk interface. If you specify a trunk interface, the VLAN associated
with that interface must have a VLAN ID.
NOTE: You cannot associate an access interface that belongs to multiple
VLANs with the MEP.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain domain-name maintenance-association ma-name mep mep-id]
user@switch# set interface interface-name
You can configure a remote MEP from which CCMs are expected. If autodiscovery is
5.
not enabled, the remote MEP must be configured under the
remote MEP is not configured under the
MEP are treated as errors.
[edit protocols oam ethernet connectivity-fault-management
maintenance-domain domain-name maintenance-association ma-name mep mep-id]
user@switch# set remote-mep mep-id

Configuring a Connectivity Fault Management Action Profile

You can configure an action profile and specify the action to be taken when any of the
configured events occur. Alternatively, you can configure an action profile and specify
default actions when connectivity to a remote MEP fails.
To configure an action profile:
Specify a name for an action profile:
1.
[edit protocols oam ethernet connectivity-fault-management]
user@switch# set action-profile profile-name
Configure the action of the action profile:
2.
Chapter 143: Ethernet OAM Connectivity Fault Management
down
so that CCMs are transmitted only out of
mep
statement, the CCMs from the remote
mep
statement. If the
4085

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents