Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 4224

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
Table 548: show oam ethernet connectivity-fault-management mep-database Output
Fields (continued)
Field Name
Field Description
Maintenance domain name format configured.
Format (Maintenance
domain)
Maintenance domain level configured.
Level
Maintenance association name.
Maintenance
association name
Maintenance association name format configured.
Format (Maintenance
association)
Continuity-check status
Continuity-check status.
Interval
Continuity-check message interval.
Maintenance association end point (MEP) identifier.
MEP identifier
MEP direction configured.
Direction
MAC address configured for the MEP.
MAC address
Whether automatic discovery is enabled or disabled.
Auto-discovery
Priority used for CCMs and linktrace messages transmitted by the MEP.
Priority
Interface identifier.
Interface name
Local interface status.
Interface status
Local link status.
Link status
Whether the remote MEP is not receiving CCMs.
Remote MEP not
receiving CCM
Whether erroneous CCMs have been received.
Erroneous CCM received
Whether cross-connect CCMs have been received.
Cross-connect CCM
received
Whether the remote defect indication (RDI) bit is set in messages that have been received. The
RDI sent by some MEP
absence of the RDI bit in a CCM indicates that the transmitting MEP is receiving CCMs from all
configured MEPs.
CCMs sent
Number of CCMs transmitted.
CCMs received out of
Number of CCMs received out of sequence.
sequence
4120
®
OS for EX Series Ethernet Switches, Release 10.4
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos os 10.4

Table of Contents